Linear Sweep Voltammetric Detection of Serum Albumin with Chromotrope 2B

SUN Wei,Han Jun-ying,JIAO Kui,LU Lu-de
DOI: https://doi.org/10.3969/j.issn.1000-0720.2005.05.016
2005-01-01
Abstract:In pH 3.0 Britton-Robinson (B-R) buffer solution chromotrope 2B may interact with protein to form a supermolecular complex. Chromotrope 2B is an azo compound and has a sensitive reduction peak at -0.48 V (vs. SCE) on the hanging mercury drop electrode. After adding human serum albumin (HSA) to above solution, the reduction peak current of chromotrope 2B decreases linearly with HSA concentration from 2.0 to 25.0 mg/L, the linear regression equation Δi_p″(nA)=50.56ρ ((mg/L))-6.72,(γ=0.995)and the detection limit of 1.84 mg/L. This method is further applied to determining the content of HSA in blood samples and the results are in good agreement with the traditional Coomassie brilliant blue G-250 spectrophotometric method.