Voltage Modulated Electrochemiluminescence for Highly Sensitive Detection

Jingjing Zhang,Rong Jin,Danjun Fang,Dechen Jiang
DOI: https://doi.org/10.7503/cjcu20200351
2020-01-01
Abstract:A voltage modulated electrochemiluminescent (ECL) method is established for highly sensitive detection. In this new strategy, a small voltage is imposed at a constant voltage that could increase ECL intensity from luminol-hydrogen peroxide by ca. 2 times. This ECL intensity shows a good linear relationship with the concentration of hydrogen peroxide in the range of 1 nmol/L-200 mu mol/L with a detection limit of 0.1 nmol/L (S/N=3). The results exhibit that the voltage modulated ECL could he an effective way to increase ECL intensity, and more importantly, used to study the electrochemical process at the electrode interface.
What problem does this paper attempt to address?