Determination of Aluminum in Natural and Drinking Waters by A. C. Oscillopolarography Using Calmagite

谭涌霞,毕树平,魏宗波
DOI: https://doi.org/10.3969/j.issn.1006-6144.2001.01.002
2001-01-01
Abstract:Determination of total aluminum in natural and drinking waters bya.c. oscillopolarography in the presence of calmagite (CLG) is presented in this paper. In 0.2 mol·L-1 NH4Ac-HAc buffer solution(pH 6.3), Al-CLG complex yields one incision on the dE/dt-E oscillogram at the potential of -0.75 V when Al is added in the solution. The incision depth is linearly proportional to the Al concentration in the range of 5×10-6~5×10-5 mol·L-1.The detection limit is 4×10-6 mol·L-1 and the relative standard deviation is 4.7% for 5×10-5 mol·L-1 Al(n=10). The proposed method has been appplied to the determination of total Al in natural waters and drinking waters. The method is found to be in good agreement with the results obtained by the ICP-AES method.