Inlfuence of atmospheric129I level on procedural blanks in analysis of ultra-low129I geological samples

Luyuan ZHANG,Ning CHEN,Xiaolin HOU,Qi LIU,Yukun FAN,Shan XING
DOI: https://doi.org/10.7515/JEE201605010
2016-01-01
Abstract:Background, aim, and scope For the purpose of geological dating using129I, low procedural background is a prerequisite for analysis of ultra-low129I geological samples generally below the level of 10?12 of129I /127I atomic ratio. Signiifcant variation of atmospheric129I level is found in a wide range of 10?10 to 10?6 of129I /127I atomic ratio on a global scale depending on the sources of129I, however, whether 129I level in air could affect procedural background during sample preparation is crucial, but unclear. Materials and methods This study performed three conventional129I analytical methods including direct precipitation of iodine, solvent extraction with CCl4, as well as combustion in a Pyrolyser furnace to compare129I /127I ratio in the procedural blanks. In the combustion method, four experimental conditions were conducted under air or oxygen as carrier gas with or without system heating. Finally,129I along with carrier iodine was precipitated as AgI, which is then dried, mixed with niobium powder and pressed in copper holder as target. 3 MV Tandem Accelerator Mass Spectrometer (AMS) was used to measure 129I in the target.Results129I /127I atomic ratios in the procedure blanks are ranging from 1.48×10?13 to 28.5×10?13. Slightly increase of129I background level was observed when NaOH solid reagent and solution stored over one year in contrast to the newly opened and prepared alkaline solution. In the three methods, the results also showed that the lowest129I /127I ratio was generated by direct precipitate method, while the highest129I background level was from the combustion method with condensed air as carrier gas. In particular, the129I /127I ratio of combustion method with oxygen as carrier gas was 2—4 times higher than the direct precipitation. Most notably,129I /127I ratio of combustion method with condensed air as carrier gas has signiifcantly raised one order of magnitude compared to the direct precipitation, especially the ifrst preparation for both experimental conditions of room temperature and heating.Discussion The results suggest procedural blanks are well controlled in our laboratory. The increase in129I /127I ratio of procedural blanks prepared with long time stored NaOH solution is attributed to the exposure of alkaline solution into the air during frequent usage, because it could easily adsorb and react with molecular iodine in the air. 129I /127I ratio in solvent extraction method (1.75×10?13 in average) was slightly higher than the lowest129I level, which indicates solvent extraction could only introduce negligible iodine during sample preparation. Obviously elevated129I /127I ratio up to 10?12 was observed for sample combustion with condensed air as carrier gas in comparison with oxygen, which is likely caused by iodine adsorption onto the plastic transfer pipe of condensed air and higher atmospheric129I level in Denmark where the experiment was conducted, rather than129I residue in the combustion furnace system.Conclusions These results suggest129I level of procedural blank could be inlfuenced by storage of samples and reagents, as well as by the degree of exchange with ambient air during sample preparation. This work shows that the procedural blank can be well controlled using the methods, direct precipitate, solvent extraction and combustion with oxygen as carrier gas, except combustion method with condensed air as carrier gas. The results suggest interfusion of air during sample preparation could increase the blank129I /127I ratio depending on the blending extent. Ultralow129I level geological samples, especially aqueous samples should be carefully stored and analyzed as soon as possible in case of atmospheric iodine adsorption. Selection of sample preparation methods needs to minimize the mixing of sample with air, especially in high atmospheric129I regions. Recommendations and perspectives In the aspect of sample preparation, geological samples for dating can be categorized to two types, high127I concentration samples and low127I concentration samples. Since the target source and AMS measurement need sufifcient stable127I amount, the former samples can be prepared by direct precipitation after simple samples pretreatment (e.g. oilfield brine by filtration through filter paper), while the latter samples have to be treated by relatively complex and long procedures for either extraction of sufifcient stable127I or addition of stable iodine carrier. On the basis of the observation in this study, therefore, it is recommended that analysis of ultra-low129I geological samples should adopt low background analytical method (combustion with pure gas as carrier gas) and performed in low ambient129I level laboratory if necessary. The iodine carrier-free or small iodine carrier addition method developed in recent years provide a great potential for geological dating of low129I and low127I samples.
What problem does this paper attempt to address?