Analytical methods for the determination of129I established at the Xi'an Accelerator Mass Spectrometry Center and application of129I as a tool to trace nuclear environmental safety in China

Ning CHEN,Wei-jian ZHOU,Xiao-lin HOU,Lu-yuan ZHANG,Qi LIU,Chao-hui HE,Mao-yi LUO,Yu-kun FAN,Zhi-wen WANG,Yun-chong FU
2010-01-01
Abstract:Nuclear safety and environmental protection is a fundamental concern for the growing nuclear power industry in China.129I can be used as an efifciency tool to trace nuclear environmental safety. The newly established 3MV Accelerator Mass Spectrometry (AMS) facility in Xi'an, with an instrument background and analytical precision of 2×10-14 and 1.75% respectively for129I/127I ratio, provides analytical capabilities to carry out129I tracer studies. Methods for different type samples preparation have been established in Xi'an AMS Center, including soil, water, plant etc. We develop a carrier free method for AMS measurement of low level129I in samples with low total iodine concentration. Samples collected adjacent to a nuclear power plant give129I/127I ratios from (0.8~1.1)×10-10, which is in same order of magnitude with the reported environmental background data, relfecting a safe nuclear environment in terms of129I.
What problem does this paper attempt to address?