Automatic Potentiometric Titration for the Determination of Calcium in Seawater

Wei ZHANG,Zhenzhen HAO,Tie LI,Maoxu ZHU
DOI: https://doi.org/10.13984/j.cnki.cn37-1141.2017.05.012
2017-01-01
Abstract:An automatic potentiometric titration method was applied to determine the concentration of calcium in seawater using EGTA (glycol-bis-(2-aminoethylether) N,N,N',N'-tetraacetic acid,C14 H24N2O10) as titrant solution and the end point was indicated with a calcium ion selective electrode.Compared with the judgment of the titration end point with an indicator reagent,the automatic potentiometric titration shows convenience to reduce the artificial error.In order to improve the analytical accuracy and precision,the working conditions were tested and the optimization was carried out.The response of the calcium ion selective electrode was rapid to calcium in seawater but extended with the addition of EGTA titrant.Thus,the dynamic equivalent point titration (DET) was chosen as the titration mode.85 % ~ 90% of the required volume of EGTA was added before titration with pause time of30 s.The minimum and maximum volumes of increment during titration should be 0.1 and 0.5 mL with the density of 1 and the waiting time of 30 s for potential response of the electrode.This method is satisfied for the determination of calcium in seawater.
What problem does this paper attempt to address?