Optimizing of the Preparation Condition of Agarose Modified Glass Slide for the Production of Protein Microarrays

JIN Shi-hui,LIU Bi-Cheng,ZHANG Chun-xiu,TANG Zu-ming,LU Zu-hong
DOI: https://doi.org/10.3969/j.issn.1671-8135.2005.02.012
2005-01-01
Abstract:Objective: To establish an optimized method for preparing protein microarray using agarose film coated glass slides and compare its protein loading capacity with aldehyde glass slide and amino glass slide. Method: Goat IgG was immobilized onto the surface of the substrates by an arrayer. After incubation, substrates immobilized with goat IgG were washed with PBS(pH 7.4) and blocked with 1% bovine serum albumin(BSA)/PBS(pH 7.4) . Substrates were then incubated with Cy3-conjugated anti-goat IgG. After wash with PBS (three times, 5min each), the slides were scanned by a laser confocal scanner. The optimal agarose concentration, NaIO4 concentration, immobilizing time, and incubating time were determined by average spot signal intensity. The protein loading capacity and linearity of the protein microarry spotted on three different substrates were investigated and compared. Result: When the concentrations of agarose and NaIO4 were 1.2% and 20ml/L respectively and the immobilizing time was one hour, and the incubating time was 45 minutes, the agarose coated glass slides based protein microarray performed best, and it had a 2.6 fold and 9 fold higher protein loading capacity than aldehyde glass slides and amino glass slides based microarrays had. Conclusion: The optimized conditions have been established and the agarose film coated glass slide is more suitable for protein microarray preparation.
What problem does this paper attempt to address?