Influence Factors Analysis on Foreign Intrusion Volume in a Simulated Water Distribution System

Hanfeng Jin,Tingchao Yu,Yu Shao,Tuqiao Zhang
DOI: https://doi.org/10.13774/j.cnki.kjtb.2016.12.017
2016-01-01
Abstract:External polluted water can intrude into water distribution systems through pipe leaks when low or negative pressure transient events occur inside drinking water pipelines. The volume of intrusion pollutants is a significant indicator that can reflect the degree of health risks when a pollution incident occurs. A pilot-scale installation was constructed in this study to simulate intrusion events, which were caused by the sudden valve closure in a laboratorial water distribution system. Intrusion volumes were measured by volumetric method and then the analysis of influencing factors for the intrusion volume was carried out. The experimental results indicated that the intrusion volume was considerably affected by the size of leakage points, initial flow rate, external pressure at leakage points, and value closing time. It had a positive correlation with the size of leakage points, initial flow rate, and external pressure, while had a negative correlation with the value closing time.