A discussion of the combined application value of FMEA and RCA in the IV infusion risk management

Wei SI,Hong-jun DI,Qiu-xia WU
DOI: https://doi.org/10.3969/J.ISSN.1672-8270.2017.06.010
2017-01-01
Abstract:Objective:To explore the combined application effect of failure mode and effect analysis (FMEA) and root cause analysis (RCA) in IV infusion risk management of pediatric outpatient so as to enhance the quality of care and ensure the safety of outpatients.Methods: For this exploration, a special analysis team was established and the flowchart was drawn up, and the potential failure modes were listed by using FMEA. And the RCA was used to analyze and evaluate the key mode in these potential failure modes so as to find the root cause might affect the safety of IV infusion, and then the improved measures were implemented and the effects of new measurement were evaluated. Results:After implemented the improved measures, the risk of top 4 risk priority number (RPN) in intravenous infusion flow decreased obviously. For the transfusion management, patients' satisfaction increased from 78.09% to 95.03% (P<0.05), and nurses' satisfaction increased from 83.79% to 97.80%(P<0.05).Conclusion: The combined application of FMEA and RCA in the IV infusion risk management of pediatric outpatient can effectively reduce the occurrence of risk events, reduce nursing complaints and disputes, and enhance the quality of nursing care.
What problem does this paper attempt to address?