Research on the value of holter monitoring in the evaluation of silent myocardial ischemia

Xiao-hua MA,Yu-rong MIN,Qi-gao ZHANG
DOI: https://doi.org/10.3969/J.ISSN.1672-8270.2015.03.15
2015-01-01
Abstract:Objective:To investigate the value of the Holter monitoring in silent myocardial ischemia (SMI).Methods: Sixty-eight patients with silent myocardial ischemia had the Holter monitoring.Results:Sixty-eight cases were detected 263 times of the SMI, Among them 05:00-12:00 highest incidence occurs 156 times total, 52.88% of the total number; second highest incidence of the time period of 18:00-22:00, total occurred 97 times, the total number of of 32.88%; 22:00-05:00 totaling occurred 46 times, the total number of 15.59%. There are a total of 187 predisposing factors array times, 63.34% of the total number. Heart rate greater than 100 bpm, SMI total array occurred 175 times, 59.32% of the total number; heart rate>65 bpm and <when 100 bpm, SMI total array occurred 78 times, 26.44% of the total number; heart rate <when 65 bpm, SMI total occurred 42 array times, 14.23% of the total number. It has obvious predisposing factors and is related to increasing heart rate.Conclusion: Holter is the main and important method to monitor and evaluate silent myocardial ischemia.