Determination of chlorhexidine gluconate in disinfection products by reversed phase high performance liquid chromatography

Yan-feng CHEN,Li LI,Yan-fang SUN,Yuan WANG,Lan ZHAO
2017-01-01
Abstract:Objective To establish a method for determination of chlorhexidine gluconate(CHG) in disinfection products by reversed phase high performance liquid chromatography.Methods CHG in samples were diluted with water,then filtrated and gradiently separated with mobile phase of acetonitrile-0.02 mol/L potassium dihydrogen phosphate (pH =2.5) by C1s column (4.6 mm ×250 mm,5 μm),and finally detected at a wavelength of 254 nm.The flow rate was 1.0ml/min with the column temperature of 35 ℃.The quantitative analysis of CHG were performed by external standard curve method.Results The method had a good linearility at the range of 0.05 mg/ml-1.00 mg/ml (r =0.999 8),with the detection limit of 0.01 mg/ml.The recovery of this method were within 97.4%-100%,and the RSDs were within 0.50%-1.57%.The separation degree of CHG met the requirements.Conclusion The method is simple,rapid,accurate and rehable,which can be used for the determination of chlorhexidine gluconate in disinfection products with different matrix.
What problem does this paper attempt to address?