Effect of Electroacupuncture on Local Extracellular Ionized Atom Concentrations at Point Zusanli (ST36)

Guang-jian ZHANG,Rui GAO,Qun-feng LIU,Hong-ying CUI,Yan-chao CUI,Jun-ke FU
DOI: https://doi.org/10.13460/j.issn.1005-0957.2017.08.0999
2017-01-01
Abstract:Objective To investigate the effect of electroacupuncture on acupoint local extracellular ionized atom concentrations under physiological status and provide a basis for exploring the mechanism of action of electroacupuncture. Method Twenty male SD rats were selected. Rat point Zusanli (ST36) was given electroacupuncture (1 mA, 0.2 ms and 2 Hz) for 60 min. Meanwhile, local tissue fluid was collected at point Zusanli and non-acupoints using a microdialyzer. The collection by molecular probe membrane sampling lasted 4 hrs: 60 min physiological status before electroacupuncture, 60 min electroacupuncture, 60 min after electroacupuncture and 120 min after electroacupuncture. Real-time analysis of the sample was made by electrolyte analysis to observe local changes in concentrations of Ca﹢﹢, K﹢, Na﹢and Cl- at point Zusanli. Result Local Ca﹢﹢concentrations at point Zusanli increased significantly during electroacupuncture (P=0.003, vs before electroacupuncture), rose gradually afterwards and reached the peak at 60 min after electroacupuncture (P=0.75, vs during electroacupuncture). Ca﹢﹢concentrations decreased at 120 min after electroacupuncture; there was a statistically significant difference comparedwith during electroacupuncture (P=0.04). Acupoint local extracellular concentrations of Na ﹢ and Cl- also increased significantly during electroacupuncture (P<0.001, P=0.007, vs before electroacupuncture) but decreased gradually during 60 min after electroacupuncture and to (71.81±15.09) mmol/L and (57.42±14.30) mmol/L, respectively, at 60 min after electroacupuncture (P=0.09, P=0.07 vs during electroacupuncture). Acupoint extracellular K ﹢concentrations had a tendency similar to those of Na﹢and Cl- but there was no statistically significant difference. Non-point electroacupuncture slightly increased extracellular concentrations of Ca﹢﹢, K﹢, Na﹢and Cl- but there were no statistically significant differences compared with before electroacupuncture (P>0.05). Conclusion Rat point Zusanli electroacupuncture can induce significant increases in acupoint local extracellular concentrations of Ca﹢﹢, K﹢, Na﹢and Cl- . Ionized atom concentrations decrease in different degrees after electroacupuncture. These provide an experimental basis for studying the physiological mechanism of electroacupuncture treatment.
What problem does this paper attempt to address?