Mini-Mental State Examination (MMSE) for the detection of dementia in clinically unevaluated people aged 65 and over in community and primary care populations.
Victoria M Thom,Rowena Milligan,S. Cullum,Martha E Watton,Demitra Tsivos,Kirsty J E Nash,A. Noel-Storr,Tracey Wing,Hosam Elhamoui,E. Phillips,Clare M Trevelyan,Sophie M Kellman,S. Creavin,Dane Rayment,S. Wisniewski,G. Singleton,Bethany E Neale,Anish S Patel,H. L. Shackleton,Thomas Hampton
DOI: https://doi.org/10.1002/14651858.CD011145.pub2
IF: 8.4
2016-01-13
Cochrane Database of Systematic Reviews
Abstract:BACKGROUND
The Mini Mental State Examination (MMSE) is a cognitive test that is commonly used as part of the evaluation for possible dementia.
OBJECTIVES
To determine the diagnostic accuracy of the Mini-Mental State Examination (MMSE) at various cut points for dementia in people aged 65 years and over in community and primary care settings who had not undergone prior testing for dementia.
SEARCH METHODS
We searched the specialised register of the Cochrane Dementia and Cognitive Improvement Group, MEDLINE (OvidSP), EMBASE (OvidSP), PsycINFO (OvidSP), LILACS (BIREME), ALOIS, BIOSIS previews (Thomson Reuters Web of Science), and Web of Science Core Collection, including the Science Citation Index and the Conference Proceedings Citation Index (Thomson Reuters Web of Science). We also searched specialised sources of diagnostic test accuracy studies and reviews: MEDION (Universities of Maastricht and Leuven, www.mediondatabase.nl), DARE (Database of Abstracts of Reviews of Effects, via the Cochrane Library), HTA Database (Health Technology Assessment Database, via the Cochrane Library), and ARIF (University of Birmingham, UK, www.arif.bham.ac.uk). We attempted to locate possibly relevant but unpublished data by contacting researchers in this field. We first performed the searches in November 2012 and then fully updated them in May 2014. We did not apply any language or date restrictions to the electronic searches, and we did not use any methodological filters as a method to restrict the search overall.
SELECTION CRITERIA
We included studies that compared the 11-item (maximum score 30) MMSE test (at any cut point) in people who had not undergone prior testing versus a commonly accepted clinical reference standard for all-cause dementia and subtypes (Alzheimer disease dementia, Lewy body dementia, vascular dementia, frontotemporal dementia). Clinical diagnosis included all-cause (unspecified) dementia, as defined by any version of the Diagnostic and Statistical Manual of Mental Disorders (DSM); International Classification of Diseases (ICD) and the Clinical Dementia Rating.
DATA COLLECTION AND ANALYSIS
At least three authors screened all citations.Two authors handled data extraction and quality assessment. We performed meta-analysis using the hierarchical summary receiver-operator curves (HSROC) method and the bivariate method.
MAIN RESULTS
We retrieved 24,310 citations after removal of duplicates. We reviewed the full text of 317 full-text articles and finally included 70 records, referring to 48 studies, in our synthesis. We were able to perform meta-analysis on 28 studies in the community setting (44 articles) and on 6 studies in primary care (8 articles), but we could not extract usable 2 x 2 data for the remaining 14 community studies, which we did not include in the meta-analysis. All of the studies in the community were in asymptomatic people, whereas two of the six studies in primary care were conducted in people who had symptoms of possible dementia. We judged two studies to be at high risk of bias in the patient selection domain, three studies to be at high risk of bias in the index test domain and nine studies to be at high risk of bias regarding flow and timing. We assessed most studies as being applicable to the review question though we had concerns about selection of participants in six studies and target condition in one study.The accuracy of the MMSE for diagnosing dementia was reported at 18 cut points in the community (MMSE score 10, 14-30 inclusive) and 10 cut points in primary care (MMSE score 17-26 inclusive). The total number of participants in studies included in the meta-analyses ranged from 37 to 2727, median 314 (interquartile range (IQR) 160 to 647). In the community, the pooled accuracy at a cut point of 24 (15 studies) was sensitivity 0.85 (95% confidence interval (CI) 0.74 to 0.92), specificity 0.90 (95% CI 0.82 to 0.95); at a cut point of 25 (10 studies), sensitivity 0.87 (95% CI 0.78 to 0.93), specificity 0.82 (95% CI 0.65 to 0.92); and in seven studies that adjusted accuracy estimates for level of education, sensitivity 0.97 (95% CI 0.83 to 1.00), specificity 0.70 (95% CI 0.50 to 0.85). There was insufficient data to evaluate the accuracy of the MMSE for diagnosing dementia subtypes.We could not estimate summary diagnostic accuracy in primary care due to insufficient data.
AUTHORS' CONCLUSIONS
The MMSE contributes to a diagnosis of dementia in low prevalence settings, but should not be used in isolation to confirm or exclude disease. We recommend that future work evaluates the diagnostic accuracy of tests in the context of the diagnostic pathway experienced by the patient and that investigators report how undergoing the MMSE changes patient-relevant outcomes.
Medicine