Comparative Study of Treating Tibial Eminence Fracture in Different Fixation Methods on Arthroscopic

Zhi-jiang LI,Lan LI,Zhen-rui LI,Wei ZHANG,Pei-fu TANG
DOI: https://doi.org/10.13241/j.cnki.pmb.2017.06.020
2017-01-01
Abstract:Objective:To investigate the effective of treating tibia1 eminence fracture in suture andwire fixation on arthroscopic.Methods:87 patients of tibial eminence fracture cases collected from Jun 2012 to Dec 2013 in our hospital,which were divided into group A (n=40),group (37 cases)B according ways of fixation,which group A was given suture fixation,and group B wire fixation,observing reset condition after 3,6,12 months,including healing time,assess knee function,range of motion of the knee,surgery time and complications.Results:Preoperative and postoperative 3 months between Lysholm score was no significant difference (P>0.05),6 and 12 months the difference was statistically significant (P<0.05);The two groups of Lyshoim score were gradually increased in preoperative,comparative with postoperative,and the difference was statistically significant (P<0.05);Operative time had no significant difference in two groups (P>0.05),and patients knee a range of motion of the comparative group of patients was significantly better than group B(P<0.05),and healing time of A group shorter than group B group(P<0.05).Conclusion:Arthroscopic suture fixation between the tibial eminence fracture with less trauma,simple,fixed solid,beneficial joint early rehabilitation,can be widely used.
What problem does this paper attempt to address?