Diagnostic Values of Whole Body Bone Imaging by 99Tcm-MDP SPECT/CT and Serological Markers for Rheumatoid Arthritis

Jia GUO,Zhi-guo WANG,Shan-hu HAO,Feng-min LIU,Guo-xu ZHANG
DOI: https://doi.org/10.11748/bjmy.issn.1006-1703.2018.03.001
2018-01-01
Abstract:Objective To investigate the diagnostic values of whole body bone imaging by 99 Tcm-MDP SPECT/CT and related serological markers(anti-CCP antibody,RF and CRP)in the diagnosis of rheumatoid arthritis.Methods A total of 164 patients with suspected rheumatoid arthritis who underwent 99Tcm-MDP SPECT/CT whole-body bone imaging in our department from January 2017 to September 2017 were retrospectively analyzed,including 72 males and 92 females,with an average age of 48-71 years old,duration of 0.5 to 2 years.All enrolled patients have relevant serological test indicators(anti-CCP antibody,RF and CRP levels),and the final diagnosis was based on the 2010 American College of Rheumatology and EUALR designated RA diagnostic classification criteria.The diagnostic performance of whole body bone imaging and serological markers were then compared.Results Among the 164 cases,128 cases of patients were confirmed. The sensitivity of serological detection was 59.38%and the specificity was 58.33%,while the sensitivity of 99 Tcm-MDP SPECT/CT bone imaging was 77.34% with a statistically significant difference(P <0.05), while the specificity was 55.56%,with no significant difference between the two groups.Conclusion In the diagnosis of rheumatoid arthritis,the sensitivity of whole body bone imaging by 99Tcm-MDP SPECT/CT is superior to the serological testing,furthermore,the whole body bone Imaging was better for assessing the systemic involvement.
What problem does this paper attempt to address?