Immunological rejection and biomechanical adaptability following xenogenic tendon defect repaired with rolled porcine small intestinal submucosa
Jian Zou,Chang-qing Zhang,Bing-fang Zeng
DOI: https://doi.org/10.3321/j.issn:1673-8225.2006.45.037
2006-01-01
Abstract:BACKGROUND: Re-injury of organism and sufficient of materials exist in the autologous transplantation of tendon to treat defected tendon following trauma. Carbon fiber artifical tendon, human hair tendon and other artifical tendons are also proved to be transplantable. But immunological rejection and biomechanical inadaptability exist following artifical tendons are transplanted. Therefore, the development of new human tendon substitute is the major problem to be solved at present.OBJECTIVE: To observe the porcine small intestinal submucosa as artificial tendon to repair 2 cm tendon defect of the 3rd toe of the left and right feet of chicken, and the immunological rejection and biomechanical adaptability following repair.DESIGN: A randomized and controlled animal experiment.SETTING: Department of Orthopaedics, Sixth Hospital Affiliated to Shanghai Jiaotong University.MATERIALS: Totally 45 Leghorn chickens, aged 12 weeks, of either gender, with body mass of 4.0 to 4.4 kg, were chosen.METHODS: This experiment was conducted at the Department of Orthopaedics, Sixth Hospital Affiliated to Shanghai Jiaotong University from September 2002 to June 2003. ① Totally 45 Leghorn chicken, aged 12 weeks, were randomly divided into 3 groups. The third toe of the left and right feet was chosen from 20 chicken respectively of autologous transplantation group and porcine small intestinal submucosa group, flexor digitorum profundus muscle tendon was cut off at middle phalanx, and 2 cm tendon defect model was created. The defected tendon in the autologous transplantation group was performed in situ suture; the defected tendon in the porcine small intestinal submucosa transplantation group was repaired with porcine small intestinal submucosa; There was not any treatment on the 5 Leghorn chicken in the blank control group. ② Histomorphologyl, transplantation immunology, biomechanics and functional recovery were measured at 3,6 and 9 weeks following tendon transplantation.MAIN OUTCOME MEASURES: ① Gross observation of operated toes of chicken and optical observation of grafts in each group. ② White blood cell (WBC) differential count at 3 days preoperation,3 days postoperation,and 1 week and 2 weeks postoperation. ③ Biomechanical test and functional recovery test of chicken in each group.RESULTS: Totally 45 chicken entered the stage of result analysis. ① At 9 weeks after operation, morphology of porcine small intestinal submucosa was basically the same as that of normal tendon by naked eyes; Under optical microscope, fibroblasts on the porcine small intestinal submucosa arranged in order along long-axis and collagen extracellular matrix appeared.② Within 2 weeks after operation, there was no significant difference of WBC measurement between porcine small intestinal submucosa transplantation group and autogolous transplantation group (P > 0.05), suggesting that porcine small intestinal submucosa, as xenogenic material, has no obvious immunological rejection. ③ In the biomechanical test, biomechanical adaptability at postoperative 12 weeks was superior in the porcine small intestinal submucosa group to in the autologous transplantation group [(22.22±0.90),(20.78±0.94) ,P < 0.05]. ④ In the test of functional recovery, there was no obvious difference of activity of metecarpophalangeal joint (P > 0.05), the activity of proximal interphalangeal joint was superior in the blank control group to in the porcine small intestinal submucosa group and autologous transplantation group [(21.0±1.6)°, (15.1±1.7)° , (16.0±2.1)° ,P < 0.05].CONCLUSION: There is no evidence of immunological rejection after porcine small intestinal submucosa is transplanted into the body of chicken. Therefore, porcine small intestinal submucosa can be used as the xenogenic material to repair tendon defect.