Reducing the Failure Rate of Magnetic Resonance Imaging in Infants
贾晓茜,郭建新,金超,李贤军,王小玗,郝辉,焦喜军,王苗苗,刘聪聪,刘衡,陶星星,程燕南,赵慧芳,李淼,张元炜,陈姣,任芳,杨健
DOI: https://doi.org/10.13912/j.cnki.chqm.2018.25.2.27
2018-01-01
Abstract:The quality control circle activity was carried out on the high failure rate of magnetic resonance imaging in infants.From the status quo,looking for problems for improvement,through the fishbone diagram analysis,key causes selection,and field validation of true causes,the true causes were determined which included unstandardized reservation process,lack of sedation assessment tool,and unreasonable sequence.The measures were developed for improvement from three aspects of establishment of education system,establishment of sedation standard,and adjustment of magnetic resonance scanning program for magnetic resonance imaging inspection among infants.The failure rate of magnetic resonance imaging among infants reduced from 29.1% to 13.6% and achieved good effect.