Measurement of Lung Function by Using Non-invasive Whole-body Plethysmograph System in Mice

Wei ZHAO,Bing YU,Shui-juan ZHANG,Yong-liang JIA,Qiang-min XIE
DOI: https://doi.org/10.3969/j.issn.1674-5817.2017.05.008
2017-01-01
Abstract:Objective To establish a method for testing pulmonary function by Buxco's non-invasive whole-body plethysmography (WBP) in mice.Methods Twenty female ICR mice were randomly divided into control group and asthmatic model group.Each mouse in model group was subcutaneously injected (multisites) and intraperitoneally injected (one site) with ovalbumin (OVA) which was dissolved in aluminium hydroxide adjuvant.OVA-sensitized mice were challenged by inhalation of antigen.For bronchial provocation test,various concentration of methacholine (Mch) aerosolized by a jet nebulizer.Respiration parameters and lung resistance,showed as the value of enhanced pause (Penh) were measured by the WBP before and after Mch challenge.Results Compared with control group,bronchial challenge of Mch dose-dependently induced significant deceleration of frequency of breathing (F) and increases of inspiration time (Ti),expiration time (Te) and the value of Penh in OVA-sensitized mice.Conclusions The results proved that the WBP of pulmonary function presented a dose-dependent on testing Mch-challenged airway hyperresponsiveness (AHR) in mice.It may be a potential testing method for AHR.