Abstract:Objective To prospectively evaluate the effect of intravenous administration of gadoxetic acid disodium (Gd-EOB-DTPA) on diffusion weighted imaging (DWI) of normal rabbit's liver on 3.0-Tesla system.Methods Six health New Zealand rabbits were performed DWI on 3.0-Tesla system before and 20 minutes after injecting Gd-EOB-DTPA (0.2ml/kg) through the left ear marginal vein with the same protocol.DWI with b values of 50,400 and 800s/mm2,and ADC values of right lateral lobe of liver were analyzed on MR Workstation.The Signal-to-noise ratio (SNR) on DWI and ADC values of the normal liver were measured and compared between these two group data by using the paired-samples t-test.Results ADC values of liver decreased slightly on 20 minutes post-contrast DWI than those of pre-contrast,(0.613 ± 0.274) × 10-3mm/ s vs (0.637 ± 0.302) × 10-3mm/s),but there was no significant difference (t=0.680,P=0.501) between them.SNRs of the liver parenchyma on DWI with different b values also showed no significant differences between 20 minutes post-and pre-contrast agent administration (P>0.05).Conclution ADC values and SNR of normal rabbit's liver on 20 minutes DWI after intravenously injecting Gd-EOB-DTPA had no significant changes compared with pre-contrast DWI.