Role of blood flow imaging technique in evaluating the thrombus before taking out the inferior vena cava filter

Ting YAN,Hong ZHANG,Peng-fei WANG,Kun ZHANG,Hai-yang FENG,Liao-yuan REN
DOI: https://doi.org/10.13507/j.issn.1674-3474.2018.05.021
2018-01-01
Abstract:Objective To explore the value of blood flow imaging technique(B-flow)to evaluating the thrombus in the inferior vena cava filter before taking it out.Methods Fifty-eight patients undergoing the implantation of inferior vena cava filter for deep venous thrombosis were taken out the filter after standardized anticoagulant therapy.Two-dimensional (2D)ultrasound,color Doppler ultrasonography and B-flow examination were performed before operation.Taking digital subtraction angiography(DSA)result as the standard,the accuracies of 2Dultrasound plus color Doppler ultrasound and 2Dultrasound plus B-flow were calculated and compared.Results DSA detected thrombus in 11cases,2Dultrasound plus color Doppler ultrasound detected thrombus in 8,and 2D ultrasound plus B-flow detected thrombus in 10.The accuracy of 2Dultrasound plus B-flow for diagnosing thrombus in the inferior vena cava filter(90.9%)was significantly higher than that of 2Dultrasound plus color Doppler ultrasound(P<0.05).Conclusion 2Dultrasound plus B-flow has a high accuracy in the detection of thrombus in the inferior vena cava filter before taking it out.
What problem does this paper attempt to address?