Early Assessment of Coronary-artery Bypass Graft with the Perioperative Ultrasonography of the Internal Mammary Artery

高俊雪,赵舟,田辉,朱家安,李建国
DOI: https://doi.org/10.3969/j.issn.1002-0101.2017.05.010
2017-01-01
Abstract:Objective To make an early assessment of the graft patency through the analysis of intraoperative and postoperative flow parameters of internal mammary artery (IMA) in patients undergoing coronary artery bypass grafting with Ultrasonography.Methods 75 cases underwent coronary artery bypass grafting.The quantity of IMA flow,pulsatility index and diastolic filling percentage were measured with TTFM.The quantity of the initial segment of IMA,pulsatility index,systolic peak velocity,diastolic peak velocity,D/S were measured with Ultrasonography 5-8 days after coronary artery bypass grafting,the flow parameters of different stages were comparatively analyzed as well.Results TTFM was performed in all the 75 cases and the display rate of the initial segment of the internal mammary artery in 5-8 days was 96%.There were significant differences in the quantity and pulsatility index of IMA in 72 cases with TTFM and postoperative Ultrasonography.Conclusions Intraoperative TTFM combining with postoperative Ultrasonography can be used to make an early assessment of coronary artery bypass graft.
What problem does this paper attempt to address?