Application of contrast-enhanced ultrasound in extrahepatic biliary ducts lesions

丛悦,吴薇,严昆,尹珊珊,戴莹,张仲一,付颖,陈敏华
DOI: https://doi.org/10.13929/j.1003-3289.2014.11.017
2014-01-01
Abstract:Objective To investigate the application value of CEUS in diagnosis of extrahepatic biliary ducts lesions.Methods Totally 45 patients with extrahepatic biliary ducts lesions were retrospectively analyzed.All 45 patients underwent ultrasound (US),CEUS and contrast-enhanced CT (CECT) before treatment.The diagnostic efficacy of imaging methods were calculated and compared.Results Benign lesions were 6 cases and malignant were 39 cases.The diagnostic accuracy of US,CEUS and CECT were 71.11% (32/45),88.89% (40/45) and 91.11% (41/45),respectively.There was significant difference between diagnostic accuracy of US and CEUS (P=0.035) and US and CECT (P=0.015).There was no difference between diagnostic accuracy of CEUS and CECT (P=1.000).Conclusion The diagnostic accuracy of CEUS for extrahepatic biliary ducts lesions is higher than US and similar to CECT.CEUS has a good value in clinical use.