Comprehensive Evaluation of Living Renal Donors Using Multislice Spiral CT: Initial Experience

ZHANG Long-jiang,WANG Lian-ying,SHEN Wen,QI Ji
DOI: https://doi.org/10.3321/j.issn:1003-3289.2007.04.028
2007-01-01
Abstract:Objective To evaluate the value of multislice CT in living renal donors. Methods Eleven renal donors were undergone three-phase enhanced MSCT scanning pre-operation. VR and MIP reformation were performed to observe renal parenchyma, renal vessels, and collecting system, and compared with operational findings in 9 cases. Results Twenty-three renal arteries, including 1 left accessory artery, appeared at MSCT; 23 renal veins, including left accessory vein in one case were present; 23 renal pelvis and ureters, including one case of right replicate renal pelvis and ureter were observed. Two accessory hepatic veins and a splenic aneurysm were detected, respectively. Two donors were abandoned because of renal vascular variants and hepatitis B.virus carrier. Intra-operational findings were consistent with MSCT findings, with the accuracy of 100%. Conclusion MSCT has an important role as a one-stop technique for the evaluation of living renal donors.