Screening Value of Neck Circumference for Obstructive Sleep Apnea in Patients with Atrial Fibrillation

汤日波,刘双,马长生,丁少芳,王丽,刘红艳,董建增,刘兴鹏,刘小慧,史力生,何华
DOI: https://doi.org/10.3760/cma.j.issn.1008-6315.2009.01.003
2009-01-01
Abstract:Objective To investigate the screening value of neck circumference(NC)and adjusted neck circumference(ANC)for obstructive sleep apnea(OSA)in patients with atrial fibrillation(AF).Methods NC and ANC were measured in 50 patients with AF who underwent polysomnography.ANC=NC+4.0 cm(if hypertension exists)+3.0 am(if habitual snore exists)+3.0 cm(if choke or gasp exists at most night).Correlation analysis and receiver operating characteristic curve(ROC)were performed to evaluate the accuracy of NC and ANC for screening OSA.Results 36 patients had OSA by polysomnography.The NC and ANC were significantly higher in the OSA group than in the no-OSA group,with the mean value of 42.3±3.3 cm VS 39.9±2.6 cm (t=2.411,P=0.020)and 49.6±4.4 cm VS 45.2±4.5 cm(t=3.168,P=0.003),respectively.NC and ANC were correlated to the severity of OSA with the r valaes of 0.566(P<0.01)and 0.629(P<0.01),respectively.There was no significant difference between the area under the ROC of NC and ANC(0.729 VS 0.746,P=0.545).At a cutoff point of 41.2 cm and 47.0 cm,the sensitivity,specificity of NC for diagnosis of OSA were 74.3%,71.4% and 71.4%.71.4%respectively.Conclusion Both NC and ANC are simple and valid indices for screening OSA in patients with AF.