Coronary artery fistula: evaluation with 320-row detector CT coronary angiography

Xiang-lan JIN,Tie-gong WANG,Bin XU,Wei YIN,Xiao-yun WU,Jian-ping LU
DOI: https://doi.org/10.3969/j.issn.1005-8001.2017.01.007
2017-01-01
Abstract:Objective To assess the value of 320-row detector CT coronary angiography (CTCA) in the diagnosis of coronary artery fistula (CAF).Methods The CTCA and clinical records of 34 patients with CAF were retrospectively analyzed.The CAF was confirmed by coronary angiography in 11 patients.Results The incidence of CAF was 0.13% (34/26,590) including 26(76.5%) coronary-pulmonary artery fistulas,3 (8.8%) coronary-left ventricle fistulas,3 (8.8%) coronary-right atrium fistulas,1 (2.9%) coronary-left atrium fistula,and 1 (2.9%) coronary-right ventricle fistula.The CAF originated fiom the left coronary artery (LCA) in 8 (23.5%),right coronary artery (RCA) in 10 (29.4%),both LCA and RCA in 16 (47.1%) patients,with associated aneurysms in 16 patients (47.1%).The diameter of the detected fistula orifice ranged from 2.0 mm to 13.0 mm,with median diameter of 2.5 mm.The fistula orifice was hyperdense (15,44.1%),isodense (9,26.5%),or showed a jet sign (10,29.4%).Conclusion The incidence of CAF was low with a predominance of coronary-pulmonary artery fistulas (76.5%).47.1% of CAF originated from both LCA and RCA.320-row detector CTCA can noninvasively and accurately show the origin,course,and diameter of the orifice as well as the drainage site of the CAF.