Value of transcranial ultrasonography in diagnosis of intracranial collateral circulation and intracranial artery stenosis with UICA occlusion

栾玉爽,白志勇,张华斌,李小刚,李敬府
DOI: https://doi.org/10.3969/j.issn.1009-0126.2015.09.018
2015-01-01
Abstract:Objective To study the value of transcervical ultrasonography in diagnosis of intracra‐nial collateral circulation and intracranial artery stenosis .Methods Blood flow in Willis circle ,in‐tracranial conducting artery and eyeground artery was detected by transcranial ultrasonography in 33 patients with unilateral internal carotid artery occlusion ,and their middle cerebral artery peak flow velocity and resistance index were recorded .Compression experiment was performed for the involved and uninvolved common carotid artery .Results The transcranial ultrasonography detec‐tion rate of collateral cucirlation was 100 .0% ,84 .6% and 56 .5% ,respectively ,in eyegroud arter‐y ,anterior communicating artery and posterior communicating artery .The middle cerebral artery peak flow velocity was significantly lower in patients with unilateral carotid artery occlusion than in those without unilateral carotid artery occlusion (74 .71 ± 13 .07 cm/s vs 100 .46 ± 19 .15 cm/s , P<0 .01) .The sensitivity and specificity of transcranial ultrasonography were 71 .4% and 92 .6%for the diagnosis of intracranial artery stenosis or occlusion .Conclusion T ranscranial ultrsonog‐raphy can show intracranial collateral circulation and blood supply with a high diagnosis accuracy of intracranial artery stenosis ,and can thus be used as an effective diagnostic method of ischemic cerebrovascular disease .