Clinical application of 18F-FDG PET/CT imaging in diagnosis of focal organizing pneumonia
周俊,毛武剑,顾宇参,余浩军,陈曙光,石洪成
DOI: https://doi.org/10.3760/cma.j.cn321828-20191205-00287
2020-01-01
Abstract:Objective:To explore the imaging features of
18F-fluorodeoxyglucose (FDG) PET/CT (high-resolution CT, HRCT) imaging in focal organizing pneumonia (FOP).
Methods:Patients with solid nodular FOP (
n=45; 33 males, 12 females, age (58±9) years) and early peripheral non-mucinous solid lung adenocarcinoma (
n=47; 21 males, 26 females, age (63±10) years) confirmed by postsurgical pathology between May 2012 and December 2018 in Zhongshan Hospital, Fudan University were retrospectively analyzed. All patients underwent
18F-FDG PET/CT (HRCT) imaging followed by surgery within 3 weeks. The imaging findings and characteristics of the lesions were recorded. Differences of the maximum standardized uptake value (SUV
max) and maximum diameter between FOP and adenocarcinoma were analyzed by Mann-Whitney
U test or
t′ test. Spearman correlation or Pearson correlation analysis was performed to analyze the relation between SUV
max and maximum diameter. Binary logistic regression analysis was performed to identify the predictive factors for FOP. Finally, the receiver operating characteristic (ROC) curve analysis was used for evaluation of diagnostic efficiency.
Results:The SUV
max of FOP was lower than that of lung adenocarcinoma (3.1(1.7, 4.9)
vs 6.5(3.8, 9.3);
z=-4.598,
P<0.01), and the maximum diameter of FOP was smaller than that of lung adenocarcinoma ((18.0±6.3) mm
vs (21.8±4.3) mm;
t′=-3.424,
P<0.01). The SUV
max was positively correlated with the maximum diameter in FOP group (
r
s=0.509,
P<0.01), while the SUV
max of lung adenocarcinoma was not correlated with the lesion size (
r=0.076,
P>0.05). HRCT of the PET/CT system showed the fusiform shape were more common in FOP (
χ2=9.549,
P<0.05). Multivariate regression analysis identified that SUV
max≤7.1, diameter≤18.3 mm, and fusiform shape were independent factors to predict FOP, with odds ratio (
OR) of 10.585, 4.674, 9.073, respectively (all
P<0.05). ROC curve analysis showed that the area under the curve (AUC) of SUV
max≤7.1 combined with diameter≤18.3 mm and fusiform nodule was 0.860, and the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 97.8%(44/45), 70.2%(33/47), 75.9%(44/58), 97.1%(33/34), and 83.7%(77/92), respectively.
Conclusion:SUV
max≤ 7.1 combined with maximum diameter≤ 18.3 mm and fusiform shape may predict solid nodular FOP.