Plasma Level of Catestatin in Patients with Different Types of Atrial Fibrillation
Liu Yuanmei,Zhu Dan,He Rong,Liu Shuwang,Yu Haiyi,Guo Lijun
DOI: https://doi.org/10.3969/j.issn.1007-5410.2015.02.002
2015-01-01
Abstract:Objective To analyze plasma level of catestatin and its clinical significance in patients with different types of atrial fibrillation. Methods A total of 84 consecutive patients with atrial fibrillation were enrolled in this study. Atrial fibrillation was categorized as paroxysmal atrial fibrillation(n = 61) and chronic atrial fibrillation (n = 23). Another 46 patients matched for concomitant diseases in sinus rhythm without any atrial fibrillation history consisted of control group. Medical history, physical examination, laboratory parameters and echocardiography were recorded. Plasma levels of catestatin were measured by ELISA and compared between groups. Results Plasma catestatin levels were decreased in overall atrial fibrillation group than in control group [0. 54 (0. 34 - 0. 96) mg/ L vs. 0. 87 (0. 59 - 1. 31) mg/ L, Z =- 3. 491, P < 0. 001]. In subgroup analysis, compared with the control group, plasma catestatin levels were significantly decreased in both paroxysmal atrial fibrillation [0. 58(0. 36 - 0. 98) mg/ L, Z = - 2. 807, P =0. 005] and chronic atrial fibrillation [0. 43 (0. 27 - 0. 78) mg/ L, Z = - 3. 450, P < 0. 001] groups. Compared with paroxysmal atrial fibrillation group, plasma catestatin levels were decreased in chronic atrial fibrillation group, although it was not statistically significant (Z = - 1. 495, P = 0. 136). Plasma catestatin levels of the patients in atrial fibrillation and in sinus rhythm at the time of catestatin sampling were similar (Z = - 0. 028, P = 0. 980), but both decreased than in the control group [0. 59(0. 33 - 0. 92) mg/ L, Z =- 3. 091, P = 0. 002; 0. 51 (0. 34 - 1. 00) mg/ L, Z = - 2. 859, P = 0. 004] . Multivariate logistic regression analysis showed that lower CST level ( OR = 0. 631, P = 0. 049 ) and elevated NT-proBNP ( > 125 ng/ L) (OR = 12. 416,P < 0. 001) were the independent predictors of atrial fibrillation. Using a receiver operating characteristic curve, the optimal cut-off value for plasma CST was 0. 73 mg/ L in the diagnosis of paroxysmal atrial fibrillation with 60. 9% sensitivity and 63. 9% specificity, the area under the curve( AUC) was 0. 659 ( P = 0. 005) . Conclusions Plasma catestatin levels of patients with atrial fibrillation are significantly decreased. Lower catestatin level may be the independent factor associated with atrial fibrillation incidence.