A comparative study of multi-slice spiral CT portography and B-mode ultrasonography in patients with cirrhosis for predicting esophageal variceal bleeding

刘文娜,宁涛,戴光荣,王剑,段世玲,冯义朝,郝婷婷
DOI: https://doi.org/10.3969/j.issn.1672-5069.2015.01.012
2015-01-01
Abstract:Objective To evaluate the accuracy of predicting esophageal variceal bleeding (EVB) in pa-tients with liver cirrhosis with three-dimensional reconstruction by multi-slice spiral CT portography (MSCTP) and hemodynamic determination of portal vein by B ultrasonography. Methods The clinical data of 60 patients with cirrhosis who were simultaneously examined by MSCTP and B ultrasonography were collected in this study. The gastroscopy was conducted in patients with EVB. Results In 60 with liver cirrhosis, the actual number of bleeding was 28. When LGV>0.61 cm and PBF>1098.36 ml/min were determined as the cut-off value for EVB, the accurate rates by MSCTP and ultrasonography were 89.29% and 60.71%,respectively (x2=6.095,P=0.029);26 out of 28 patients with EVB was confirmed by gastroscopy,and no esophageal varices bleeding in the other 2 cases;MSCTP and gastroscopy had no significant difference in predicting EVB (P=1.000) as determined by McNe-mar test,and Kappa coefficient analysis showed substantial consistency of these two methods (matching coefficient K=0.781,P=0.000);While there was a significant difference between ultrasonography and gastroscopy in predicting EVB(P=0.012),and Kappa coefficient analysis showed slight consistency of these two methods (matching coeffi-cient K=0.038,P=0.747). Conclusion MSCTP can predict EVB,and has a good consistency with gastroscopy.
What problem does this paper attempt to address?