Detecting the Causes of Common Bile Duct Dilation by Endoscopic Ultrasonography

韩树堂,徐肇敏,吕瑛,陈隆典
DOI: https://doi.org/10.3760/cma.j.issn.1007-5232.2001.02.006
2001-01-01
Abstract:Objective To detect the causes of common bile duct (CBD) dilation by endoscopic ultrasonography (EUS). Methods Thirty-two cases were included in the study. These patients had been undergone the examinations for common bile duct dilation firstly by B-mode ultrasonography then by endoscopic ultrasonography, computed tomography (CT), endoscopic retrograde cholangiopancreatography (ERCP), endoscopic sphicterotomy(EST), magnetic resonance cholangiography(MRCP) The causes of CBD dilation in these patients were determined by surgery and/or pathologic histology (the stones in CB D were diagnosed by ERCP/EST). Results The average diameters of CBD were 1.04 ± 0.41 cm and 0.97 ± 0.36 cm respectively as detected by abdominal B-mode ultrasonography (US) (32 cases) and EUS (29 cases) (P>0.05). The positive rate of diagnosis for the causes of CBD dilation were 90. 6% (29/32) by EUS , which was superior to 59. 4% (19/32) by US(P<0.01) and 65.6% (21/32) by abdominal CT(P<0.01) and close to 96.9% (31/32) by ERCP/ES (P>0.05) and 81.3% (13/16) by MRCP ( P>0.05). Conclusion Endoscopic ultrasonography is one of the best methods for diagnosis of common bile duct dilation.
What problem does this paper attempt to address?