Abstract:Objective To evaluate the efficacy and safety of endovascular brachytherapy using a simple system of a 32 P or 90 Y liquid-filled balloon catheter on the prevention of restenosis after interventional therapy. To observe the dose-effectiveness relation and to investigate its possible mechanisms. Methods In the balloon-injuried rabbit model, Eighteen balloon-injuried rabbits were used in the study, 32 P or 90 Y Liquid was filled into the balloon catheter system and radiative balloon was positioned on the one side of rabbit iliac artery after balloon over-stretching, on the other side non-radiative balloon inflation was served as the placebo. After five weeks, the iliac artery angiography was performed, pathological sections of iliac arteries were observed and the changes of vascular histomorphology were estimated by computer analysis of photomicrograms. Using immunohistochemical techniques, proliferating cell nuclear antigen (PCNA) was quantified to assess the proliferation of vascular smooth muscle cells, and matrix synthesis estimated by collagen staining. Results After five weeks, the target vessel of placebo stenosis 77% in average; the 24 Gy vessel 13% in average;the 16 Gy vessel 30% in average;the 8 Gy vessel 76% in average. HE-stained sections were morphometrically analyzed, the external elastic lamina (EEL) area, intimal elastic lamina (IEL) area, neointimal area, luminal area in 24 Gy and 16 Gy vessel compared with self-controlced respectively P<0.01; in 8 Gy vessel compared with self-controlled respectively P>0.05; except 8 Gy vessel compared with the placebo (P>0.05), neointimal area in the other groups compared with placebo remarkably inhibited (P<0.01), the dose-effectiveness relation was observed. The percentage of PCNA positive cells by staining was (84±5)% in the control and (77±3)%, (44±5)%, (21±6)% in the therapy vessel of 8 Gy, 16 Gy, 24 Gy respectively and except 8 Gy vessel compared with the placebo (P>0.05), the other groups compared with placebo (P<0.01),the dose-effectiveness relation was observed. Conclusion A significant effect of high-energy β-radiation to reduce neointima formation and increase lumen size was observed in enough dose groups. Endovascular brachtherapy using liquid 32 P or 90 Y-filled balloon catheter system could prevent restenosis, the mechanism may be due to inhibit the proliferation of neointima and the vascular negative remodeling.
What problem does this paper attempt to address?