Radiofrequency catheter ablation of atrial tachycardia guided by high-density mapping using EnSiteNavX system

Xian-zhang ZHAN,Shu-lin WU,Ping-zhen YANG,Yu-mei XUE,Xian-hong FANG,Hong-tao LIAO,Yuan-hong LIANG,Wei WEI,Fei-ai MENG
DOI: https://doi.org/10.3760/cma.j.issn.1007-6638.2010.06.012
2010-01-01
Abstract:Objective To investigate the efficacy of high density mapping using EnSite-NavX system for radiofrequency catheter ablation of atrial tachycardia (AT). Methods Fifteen patients with AT in our hospital were retrospectively analyzed. Among the 17 pts,the mean age was(45.9 ± 16. 9) years( 15 male,2 female). All sustained AT were mapped by high density mapping using EnSite-NavX system. The critical reentry isthmus or the focal origin was identified by constructing three-dimensional model of atrium and the activation map of AT. Irrigated tip radiofrequency catheter was used for ablation. Results There were 19 types of AT in 17 patients. The cycle lengths of AT were (254 ± 49 ) ms. The mean high density mapping points were (316 ± 90). The mean high density mapping time was( 8.4 ± 2. 6 ) mins. Nineteen types of activation sequences of AT were mapped,including 10 reentrant AT and 9 focal AT. Acute successful ablation was obtained in 18 of the 19 AT. The complications related to mapping and catheter ablation were not detected. During(3.0 ± 1.6) months follow-up,amiodarone prevented relapse of AT in two patients. Conclusions High density mapping using EnSiteNavX system can detect AT efficiently and accurately. It may improve the success rate of catheter ablation of AT.