Volar Approach Percutaneous Minimally Invasive Treatment for Scaphoid Fracture with Herbert Screw:Report of 11 Cases

吴伟,刘晓峰,严松鹤,王建伟
DOI: https://doi.org/10.3969/j.issn.1009-6604.2017.06.017
2017-01-01
Abstract:Objective To explore the clinical effect of acute scaphoid fractures treated by closed reduction and Herbert screw fixation.Methods A retrospective study was carried out on 11 patients with acute scaphoid fractures treated by percutaneous fixationa with Herbert screw from the palm side from September 2012 to September 2016.The fractures were categorized according to the Herbert classification with 8 cases of type A2,2 cases of type B2,1 case of type B3.Results The operation time was 45-80 min(mean,65 min).The bleeding during surgery was 2-30 ml(mean,11 ml).The intra-and post-operative X-ray examinations confirmed that the fracture reduction was good and the screw position was correct.In two weeks after surgery,the wound healed after stitches were taken out.All the patients were followed up for 3-18 months (mean,8 months).Bone union was obtained in all the patients.By using the Mayo wrist scores,excellent results were achieved in 9 cases,good in 1,and general in 1.The rate of excellent and good result was 90.9% (10/11).Conclusion Percutaneous closed reduction and Herbert screw fixation for acute scaphoid fracture are effective.
What problem does this paper attempt to address?