Midterm follow-up of long handle prosthesis-Solution extensively titanium porous coated stem with wire cerclage in revision of Vancouver type-B2 periprosthetic femoral fractures after hemiarthroplasty

Hai LI,Zongke ZHOU,Fuxing PEI,Bin SHEN,Jing YANG,Pengde KANG
DOI: https://doi.org/10.3969/j.issn.1674-1439.2014.02-001
2014-01-01
Abstract:Background: Patients with Vancouver type-B2 periprosthetic femoral fractures after hemiarthroplasty often are elder with much more co-morbidities and poor bone condition. The perioperative management and surgical technique are very diffi-cult, and the incidence of complications is very high. <br> Objective:The aim of the study is to evaluate the intermediate-term curative effect of long handle prosthesis-Solution exten-sively titanium porous coated stem with wire cerclage in revision of Vancouver type-B2 periprosthetic femoral fractures af-ter hemiarthroplasty. <br> Methods:Clinical data of 14 patients with Vancouver type-B2 periprosthetic femoral fractures after hemiarthroplasty treated between January 2008 and December 2012 in our hospital were retrospectively analyzed. There were 6 males and 8 females, with a mean age 70.3 years (range from 66 to 80 years). All of them received open reduction, internal fixation, and revision with Solution stem. Hip Harris score was assessed at the last follow-up after surgery. Radiographs were taken before sur-gery, 3, 6, 12 months after surgery and the last follow-up to assess the fracture restoration and healing, prosthesis initial fixa-tion and intermediate-term survival condition. <br> Results:Sixteen patients, 1 case died of lung cancer 3 years after surgery, 1 case loss of follow-up, 14 cases were followed up 3-5 years, mean 4.2 years. Preoperative hip Harris score was not obtained because of fracture, and the mean Harris score was 88.7 at the last follow-up. Radiographs showed reduction of fracture was successfully achieved, the fixed length of the stem surpassing fracture line were more than 5 cm, and the femur was well pressed-fit well. The average healing time of&nbsp;fracture was (3.8±1.3) months (range, 3-6 months). There were no loosening, subsidence of Solution stem at the last follow-up. No infection, deep vein thrombosis and pulmonary embolism occurred. <br> Conclusions: The mid-term curative effect of the long handle prosthesis-Solution extensive porous titanium coating stem with wire cerclage in revision of Vancouver type-B2 periprosthetic femoral fractures after hemiarthroplasty is good. The long term results need further follow up.
What problem does this paper attempt to address?