The study of the feasibility,safety and clinical efficacy of microendoscopic discectomy(MED) assisted thoracolumbar pedicle screw placement technology

Da-peng FU,Jian-min LU,Song-hua XIAO
DOI: https://doi.org/10.3969/j.issn.1009-4237.2017.02.004
2017-01-01
Abstract:Objective To observe the feasibility ,safety and clinical efficacy of microendoscopic discectomy ( MED) assisted thoracolumbar pedicle screw placement technology .Methods Eighty patients with thoracolumbar fractures received simple minimally invasive pedicle screw fixation in our hospital from Jan .2012 to Jan.2014 peri-od were selected as research subjects .They were randomly divided into two groups with 40 patients in each group . Patients in the two groups underwent routine examination .The control group was treated by percutaneous hollow pedicle screw implantation with Sextant system ,while the study group was treated with MED assisted ordinary pedicle screw implantation.The operation time,intraoperative blood loss,length of incision,exposure times,ease of opera-tion,TLICS score,VAS score,JOA score,complication rates,length of stay,hospital cost,treatment satisfaction after surgery were recorded and compared between the two groups .Results Operation time,blood loss,TLICS score, VAS score,and the length of hospital stay between the two groups were compared , and the difference was not statisti-cally significant ( P>0.05 ) .The hospital cost of the study group was significantly lower than that of the control group,and the difference was statistically significant ( P<0.05).Complication incidence of the study group was 5.0%,while that in the control group was 7.5%,the difference was not statistically significant (P>0.05).After treatment,the total satisfaction rate of the study group was 92.5%,while total satisfaction rate in the control group was 75.0%,the difference was significant .Before surgery ,JOA score of the two groups was not significantly different&nbsp;(P>0.05).After surgery,both groups had significant changes in JOA score ,and the degree of change in the study group was significantly higher than that in the control group with significant difference (P<0.05).Conclusion MED assisted thoracolumbar pedicle screw placement in the treatment of thoracolumbar fractures can significantly re -duce the times of exposure and the cost of treatment .It can make the surgical procedure easier and greatly reduce the risk of surgery .It is safe with high clinical value ,and worthy of promotion .
What problem does this paper attempt to address?