Comparison of bone mineral density measured by quantitative computed tomography and dual energy CT at the lumbar spine

Ping WANG,Jianwei HE,Gang HUANG,Zeqing MAO,Xing ZHOU,Wenwen ZHANG,Yanan ZHAI
DOI: https://doi.org/10.3969/j.issn.1006-7108.2017.02.005
2017-01-01
Abstract:Objective Lumbar spine bone mineral density was measured by dual energy CT (DECT) and quantitative CT (QCT),with the aim of assessing the feasibility of using dual energy CT for the measurement of bone mineral density (BMD).Methods Totally 56 volunteers were enrolled and underwent dual energy CT (DECT) to obtain the CT attenuation value of bone calcium and bone marrow and also underwent quantitative CT (QCT) to obtain BMD at lumbar spine (L1-L5) in the same scan.The correlation between CT attenuation value of bone calcium and bone marrow with BMD was analyzed.Results The CT attenuation value of bone calcium was significantly positively correlated with BMD at the lumbar spine,the Pearson correlation coefficients of L1-5 vertebral body were r =0.715,0.692,0.739,0.673,0.686,respectively,P < 0.001.The CT attenuation value of bone marrow was positively correlated with BMD,the Pearson correlation coefficients of L1-5 vertebral body were r =0.343,0.315,0.439,0.440,0.456,respectively (L5 P < 0.05,L1 to L4 P < 0.01).Conclusion The CT attenuation value of bone calcium and bone marrow is closely correlated with BMD value measured by QCT at lumbar spine,which can indicate quantitative BMD.
What problem does this paper attempt to address?