Assessment of the reasons for revision surgery after interspinous dynamic stabilization

朱震奇,刘海鹰,刘辰君,段硕,王凯丰,徐帅
DOI: https://doi.org/10.3977/j.issn.1005-8478.2018.07.02
2018-01-01
Abstract:[Objective] To explore the reasons of revision surgery after interspinous dynamic stabilization.[Methods] From Dec 2010 to Dec 2016,11 patients who received interspinous dynamic stabilization (Wallis or Coflex implants) from Mar 2009to Oct 2013 had revision surgery due to various reasons,as well as both the primary and revision surgeries were conducted in our department.Of them,9 males and 2 females aged from 26 to 77 years with an average of 57 years at the primary surgery.The clinical and imaging data,such as X-ray,CT and MRI before and after both the primary and revision surgeries,were compared and assessed.[Results] The time spanned 3.75 years on average between the primary and revision surgeries.Based on clinical and imaging data,the reasons for revision surgery were deduced improper indication selection,adjacent segment disease,spinous fracture or bone resorption,and chronic infection.Among them,the improper indication selection was subdivided into severe lumbar spinal stenosis,obvious segmental instability,scoliosis and severe osteoporosis.[Conclusion] The improper indication selection of interspinous dynamic stabilization with Wallis or Coflex,such as severe lumbar spinal stenosis,obvious segmental instability,lumbar scoliosis and severe osteoporosis is the major reason of primary operation failure.In addition,the adjacent segment disease,spinous fracture or bone resorption and chronic infection secondary to the dynamic stabilization should be paid attention to.
What problem does this paper attempt to address?