Supporing Screws and Bbone Cement Filling Combined with Intramedullary Stem for Reconstruc-ting Tibial Bone Defect and Joint Stability in Total Knee Arthroplasty

潘文杰,贺艳,马建兵,肖琳,卿忠,王曦,姚舒馨,武淑芳
DOI: https://doi.org/10.13795/j.cnki.sgkz.2016.10.005
2016-01-01
Abstract:Objective To observe the early clinical effect of Supporing screws and bone cement filling combined with intr-amedullary stem for reconstructing tibial noncontained bone defect and joint stability in primary total knee arthroplasty. Meth-ods From May 2012 to October 2015,16 patients(21 knees)with tibial plateau noncontained bone defects including 4 men (5knees)and12 women(16 knees)underwent primary total knee arthmplasty. The average age of the patients was 70. 5 years old ranging from 65 to 76 years. The average weight was 75. 6 kg ranging from 68. 5 kg to 92 kg,and the average body height was 171. 1 cm ranging from 155 cm to 180 cm. The diagnoses of the patients were osteoarthritis in 13 cases(16 knees)and rheumatoid arthritis in 2 cases(4 knees),Kashin-Bek syndrome in 1 case(1 knee). The preoperative range of movement (ROM)was(69. 8 ± 9. 8)°. According to Knee Society score(KSS)criterion,the clinical score of preoperation was(31. 9 ± 8. 8)and functional score was(33. 1 ± 9. 1)During operation,the average depth of tibial plateau defect was 19. 8 mm before tibial osteotomy. The conventional tibial osteotomy of 10. 0 mm was performed,the average depth of the residual bone defect was10. 5 mm. Sclerotic bone was thoroughly removed,2 or 3 pieces of supporting screws were inserted according to bone defect area and morphology,and bone cement was pressurely filled,and then the tibial prosthesis with stem was installed. Results All the cases were followed up of 26. 5 months(range,3 to 36months). All the patients can walk without crutch and self-care 1 month after operation,The enstrophy or ecstrophy or contraction anisotrophy were completely rectified right after operation,and the pain of knee was totally reliefed,At the latest follow-up,the KSS clinical score was knee score(90. 3 ± 9. 0)and functional score was(91. 4 ± 8. 3). The ROM of the knee joint was(115 ± 8. 8)°. In the final follow-up through the X-ray measurement, the position of the prosthesis was good,and no loosening or signs of infection. The radiolucent of bone cement filling zone inter-face,loosening or displacement of the supporting screw,and other complications were not found in cases. Conclusion Suppor-ing screws and bone cement filling can repair noncontained bone defect,restoring the joint line level,and intramedullary stem can increase the stability of the knee in primary total knee arthroplasty. The function of knee was excellentand early clinical ef-ficacy is satisfactory.
What problem does this paper attempt to address?