Ultrasound Guided Percutaneous Transforaminal Endoscopic Lumbar Discectomy with No Radiation: a Case Report

Zhang Mingbo,Huang Peng,Wu Chengzhi,Yan Longtao
DOI: https://doi.org/10.3877/cma.j.issn.1674-6899.2019.02.012
2019-01-01
Abstract:Objective To explore the possibility of ultrasound guided percutaneous transforaminal endoscopic lumbar discectomy (PELD) with no radiation.Methods The lumbar transverse processes were used as the markers to locate the target level on longitudinal section.A hyperechoic zone on transverse section of lumbar ultrasound was used as the marker to puncture and cannulation of PELD,and the operation was completed.Results After operation,the symptoms were relieved obviously.Postoperative MRI showed that the solid tissue of nucleus pulposus in the herniated disc had been completely removed,and the nerve root had been completely released without complications.Conclusions This is the first case of zero radiation PELD guided by ultrasound in the world (Report of Novelty Search of Medical and Health Science and Technology No.2019023;Novelty Search Station of Medical and Health Science and Technology,General Hospital of PLA;Novelty Search Time,March 18th,2019).It has important value to further reduce the radiation dose of PELD during puncture and intubation under the guidance of ultrasound.
What problem does this paper attempt to address?