The Measurement of Trajectory Parameters in Posterior Atlanto-Occipital Transarticular Screw Fixation

严望军,张咏,周许辉,李家顺,贾连顺
DOI: https://doi.org/10.3969/j.issn.1672-2957.2005.01.009
2005-01-01
The Journal of Spinal Surgery
Abstract:Objective To explicit the technical parameters in posterior atlanto-occipital transarticular screw fixation; To discuss the clinical significance of craniovertebral junction fixation with transarticular screws. Methods Posterior atlanto-occipital transarticular Kirschner wire implantation was performed under visual control on 30 dried bony specimens that contained complete atlanto-occipital articulations, and cephalocaudal and lateral views were filmed by X-ray, on which the angle and length of the screw trajectory were measured. Results The ideal angle of the atlanto-occipital transarticular screw trajectory was as follows: 53.3°±3.4° upper tilting in sagittal plane and 20.0°±2.6° inside tilting in coronary plane. The length of the trajectory was (29.28±2.46)mm. Conclusion Posterior atlanto-occipital transarticular fixation is clinically feasible; there is a definite direction for implanting the screws and an adjustable range for the allowable length and angle of the trajectory. Posterior atlanto-occipital transarticular fixation can be considered to be an ideal fixation modality for craniovertebral fusion combined with C 1 and C 2 transarticular fixation.