Hybrid surgical treatment using self-made intraluminal shunt for complicated Stanford B type aor-tic dissection

陈浩,王志维,夏军,吴红兵,邓宏平,吴智勇,徐鹏,周桢
DOI: https://doi.org/10.3969/j.issn.1005-6483.2015.01.017
2015-01-01
Abstract:Objectives To summarize the experience and methods of hybrid surgical treatment u-sing intraluminal shunt for complicated Stanford B type aortic dissection. Methods A total of 40 patients with complicated acute Stanford type B aortic dissection received hybrid procedures. Cervical arteries were reconstructed by using self-made intraluminal shunt to keep carotid arterial blood circulation. Results All the 40 patients were successfully operated. No patient experienced acute intracranial manifestations and left upper limb ischemia. Proximal crevasse were perfectly closed without endoleak and the vascular bypasses were unobstructed. There were 2 cases of perioperative death. One patient had type A aortic dissection at the 3rd day after operation. Other complications included acute renal failure(1 case),the left hemothorax (1 case)and temporary psychiatric symptoms(6 cases). A total of 38 patients were followed up,but 2 of them were lost and one of them died within the 1st week after discharge. Postoperative review at the first month and the first year showed no intracranial manifestations or left upper limb ischemia. Aortic CTA re-view showed good graft patency without stent displacement and endoleak. Conclusion Hybrid procedure is a safe and effective treatment for complicated Stanford type B aortic dissection. Self-made intraluminal shunt can maintain the carotid artery blood flow and reduce the occurrence of cerebral ischemia.
What problem does this paper attempt to address?