Characteristics of Rat C6 Glioma Model on 7T Animal MRI
Bing-cang HUANG,Dao-ying GENG,Pei LIU,Hai-ning ZHENG
DOI: https://doi.org/10.3969/j.issn.1006-5741.2011.06.017
2011-01-01
Abstract:Purpose:To establish the model of rat C6 glioma and study their features with 7T animal MRI,including conventional MR imaging,DWI,MRS and PWI.And to optimize the MR imaging sequences and parameters.Methods:Forty SD rats with body weight 200g were chosen and implanted C6 glioma cells at right caudate nucleus of the brain through stereotaxic apparatus to establish rat brain glioma models.The location of needling was about 1mm lateral to biparietal suture and 3mm right of arcuate suture.The depth of needling was 5mm and back 1mm.The total needling liquid was 10ul with cell density of 2×10~5/μl.The total needling time was about 10 minutes.The needle was drawn after 5 minutes. Seven days after glioma cells implanting,all rats were examined with MRI to choose the rat glioma of the same size and location for study.The chosen 30 rats were examined with conventional MRI,DWI, MRS,and PWI.After MRI examination,the rats were sampled for electronic microscopy and pathology exam.Results:After 7 days development of the tumor,the success rate was 100%.The average volume of glioma was 0.15cm~3.C6 rat brain gliomas were proved by pathology and microscopy.The golimas were with long T_1 and long T_2 signal on routine MRI,high signal on DWI.The average rADC value was 0.70×10~(-3)m/s.The baseline of MRS was stable and the ratio of area under peak of Cho/Cr,NAA/Cr,Lac/Cr, Lip/Cr and Cho/NAA was 1.22,1.67,1.70,0.76,0.75,respectively.The PWI curve was stable and the average rrCBV value was 3.73.Conclusion:The model of rat brain glioma could be established by implanting C6 glioma cells through stereotaxic apparatus.The 7T MRI images of all sequences are clear and stable,the optimal parameters of 7T MRI sequences are found successfully,so they are useful for future experiment.