DEVELOPMENT OF NEW-GENERATION DENTAL NONMETAL POSTS BY GLASS FIBER REINFORCED ACRYLIC RESIN

张文云,施长溪,陈吉华,姚月玲
DOI: https://doi.org/10.3969/j.issn.1008-6455.2001.01.004
2001-01-01
Abstract:Objective: To study the mechanical property of acrylic-based resin reinforced by high-strength glass fibers; To explore the proper method of producing composite resin post and core.  Methods: 48.7%, 56.8%, 72.4% (w/w) of S glass fibers were added into acrylic-based resin respectively to prepare fiber-reinforced composite resin (FRC) in a unilateral form. The transverse strength, shear strength and fracture load of the materials were measured. Pre-impregnated material is pressed into dental post in the self-made mould and fiber volume is measured.  Results: The fracture load and Young's moduls of the FRC were increased with the increase of S-glass fiber volume (P<0. 01). The highest fracture load and Young's modulus values were obtained in the FRC with 72.4% S-glass fibers and were (1414.7+64. 5) Mpa and (39. 6± 1.6 ) Gpa respectively; The fiber volume of post is (68.38±1.67) %.  Conclusion: The flexure property of acrylic-based resin can be reinforced by the incorporation of S-glass fibers. The post made by high-strengthen glass fiber reinforced dental acrylic resin could be used in clinic successfully.
What problem does this paper attempt to address?