Correlative analysis between contrast-enhanced ultrasonography and 99mTc-DTPA renography in evaluation of renal insufficiency

Yi DONG,Wen-ping WANG,Jia-ying CAO,Pei-li FAN,Xi-yuan LIN,Peng-cheng HU
DOI: https://doi.org/10.3760/cma.j.issn.1001-7097.2010.07.007
2010-01-01
Abstract:Objective To evaluate the contrast-enhanced ultrasonography (CEUS) in quantitative diagnosis of chronic renal insufficiency. Methods Correlation of CEUS indexes with glomerular filtration rate (GFR) detected by 99mTc-DTPA renography was examined. Thirty-three cases of clinical chronic renal insufficiency were enrolled in the study. They were 15 males and 18 females with average age of (43.33±6.78) years. After intravenous bolus injection of 1 ml SonoVue,CEUS of renal cortex blood perfusion was performed successfully, and a time-intensity curve (TIC)was created with PHILIPS iU22 system's QLAB software. A 148 to 222 MBq dose of 99mTc-DTPA was injected as a bolus from antecubital vein. Renal scintigraphic images were collected immediately and GFR was obtained. Results The significant correlation coefficients between GFR and CEUS quantitative indexes were as follows: rAUC (area under curve)=0.886 (P<0.05), rA (slope rate of ascending curve, A) =0.804(P<0.05). However, rDPI (derived peak intensity, DPI)=0.021 (P>0.05), rTTP (time to peak, TTP) =0.043 (P>0.05), rα (slope rate of descending curve,α)=0.039 (P>0.05). Conclusion CEUS can precisely display the hemodynamic change of chronic renal insufficiency, which is well correlated with GFR by 99mTc-DTPA renography.
What problem does this paper attempt to address?