Analysis of Screw Distribution in the Humerus Head in Proximal Humerus Fracture Treated with Proximal Humerus Internal Fixation Locking System

Jing Zhou,Wei Huang,Weicheng Lin,Tianbing Wang
DOI: https://doi.org/10.3877/cma.j.issn.2095-5790.2015.02.003
2015-01-01
Abstract:Background Proximal humerus fracture is one of the fractures that easily occur in human body .It is a fracture around joints so there are specific treatment ways .As the aggravation of aging society ,the osteoporosis population is getting larger .Osteoporosis has become an important issue in the traumatic orthopedics treatment .How to increase the stability of fixation in osteoporosis fracture and how to make sure stability of the bony union in fracture are becoming challenges for traumatic orthopedists .Proximal humerus fracture is one kind of osteoporosis fractures .Proximal Humerus Internal Locking System (PHILOS) has a stable angulation of screws locking as well as assembly of multi‐directions of screws inside the humerus heads .These characteristics increase the stability of fixation and lead to the wide clinical application .This research analyze the humerus head screws distribution in proximal humerus fracture treated by PHILOS .Methods General data:inclusion criteria of cases :(1 ) proximal humerus fracture;(2 ) CT on the shoulder joints before operation;(3) accept the PHILOS operation .From December 2007 to August 2014 ,41 patients who reached the above‐mentioned criteria were selected as the study subjectives .They were patients with fresh fractures and 15 were males and 26 were females .And their average age was 67 .7 years old (from 42‐89 years old) .All patients should have CT of the shoulder joints before the operation .They will get general anesthesia and the operation position is beach chair position .The incision will be performed from the deltopectoral approach .PHILOS from Synthes is selected as the internal fixation device .Date measurements :The contralateral shoulder joint cross section on the CT was selected as the measurement data .The measurement index was the included angle α between the ideal center distribution lines in the humeus head screw s (mark as"a") and the real center distribution line (mark as "a′") .Line a is the perpendicular line of humerus head ,line a′is the perpendicular line of PHILOS board .And given that the PHILOS plate usually is placed on the greater tuberosity ,line a′is also the perpendicular line of the greater tuberosity .Each contralateral shoulder joint cross section on the CT is marked with the above‐mentioned two lines ,and their included angle is measured .Statistical method:The included angle α in each case was set and the average value was calculated .Results The body coronal plane was defined as the datum line which can be observed in the contralateral shoulder joint cross section on the CT .The included angle between line a′ and the coronary plane were all smaller than the included angle between line a and the coronary plane .Namely ,line a is further away to the coronary plane than line a′.The included angle α between line a and line a′was from 0°to 54 .3° ,and the average value was 20 .8° .Conclusion When PHILOS treating proximal humeral fracture ,the distribution of screws inside the humerus head overall toward the front side ,and the distribution of fixed screws inside the humerus head is uneven ,which needs to be improved .
What problem does this paper attempt to address?