A comparative study between magnetoencephalography resting-state neural networks ;and electrocorticography locating

吴婷,刘宏毅,张锐,陈奇琦,杨露,张远超,蒋田仔
DOI: https://doi.org/10.3969/j.issn.1672-7770.2015.03.003
2015-01-01
Abstract:Objective To explore the consistency of magnetoencephalography ( MEG ) resting-state neural networks and electrocorticography ( ECoG ) locating .Methods 16 patients with refractory epilepsy were recruited and MEG resting-state neural networks and ECoG were located before surgical operation to contrast the consistency .Results Spikes were observed in 16 patients, and located focally in 10 and sporadically 6 by Dipole.Single focus in 11 patients and multiple lesions in 5 patients were located by SAM .The resting state brain network of all patients were abnormal,the sensitivity was 100%(16/16).The coincidence rate was 62.5%(10/16) between Dipole and ECoG, 68.7%(10/16) between SAM and ECoG , 81.2%(13/16) between MEG and ECoG locating seizure onset zones , 100% between MEG and ECoG locating resting state brain network .Conclusion MEG resting-state neural networks may locate locate seizure onset zones , and contribute epilepsy operation .
What problem does this paper attempt to address?