The experimental study and clinical application of temporary intravascular catheter in treating amputated limb

张建磊,丛锐,陈永祥,臧成五,赵睿,史林
DOI: https://doi.org/10.3969/j.issn.1671-2722.2017.01.002
2017-01-01
Abstract:Objective To explore the application of temporary intravascular catheter using on amputated limb in order to quickly recover blood supply, and to study the material of temporary intravascular catheter and the effectiveness evaluation of blood supply within a short time. Methods There were 40 experimental piglets which were divided into groups A and B randomly. They were established to amputated limb model using the small diameter intravascular catheter of inner diameter of 2.0 mm, outside diameter 2.5 mm and length 18cm. Group A was made of Heparinization polyethylene pipe. Group B was Medical silicone tube. To observe the patency rate after vascular bridge connection. The observation endpoints with the temporary intravascular catheter completely blocked were as follow: no blood flow signal on Doppler ultrasound, and no pusle in distal blood vessel, and distal amputated limb without bleeding. Comparing the different time endpoints of two groups. Clinical application: Heparinization polyethylene pipes (2.0 mm ×2.5 mm) were used into two patients with amputated limb injury. It was used to connect radial artery and cephalic vein of the broken ends in order to establish the temporary vascular access and observe the effect. Results After established temporary vascular access, the distal femoral artery of amputated limb started to pulse, and vascular Doppler ultrasound could detect the signal of blood flow. With the extension of time, the color of diameter intravascular catheter changed from red to dark red with the thrombus formation in inner catheter. The pulse of distal vascular were gradually weakened. The exudation of subcutaneous blood capillary net were also disappeared. The time endpoint of two groups were respectively A group (370±52.5 min) and B Group(192±54.0 min). Compared with the differences between two group, it had statistical significance (P<0.05). To show that Heparinization polyethylene pipes was better than Medical silicone tube in experimental animals. 2 cases were used with temporary intravascular catheter in clinical. Firstly, we established the temporary blood circulation with temporary intravascular catheter in preoperative time.The mean time was 3.5 hours. Secondly, we used this time to fix bone fracture and repair nerve and tendon. Finally, when we started to anastomose blood vessel, intravascular catheter was still open. After surgery, amputated limb was survived. Conclusion Temporary intravascular catheter can be used in amputated limb, in order to bridge vascular temporarily. It can maintain (370 ±52.5) min. And effective time is longer than others. Experimental data shows that its blood compatibility, physical property and anticoagulation is suitable for amputated limb at urgent situation. It can be widely used into the complicated injury of amputated limb in clinical application to short time of limb ischemia and decrease ischemia reperfusion injury provided prerequisite for saving amputated limb, especially undercomplex battle circumstances.
What problem does this paper attempt to address?