A novel gradient degradable ureteral stent

Boxin Xue,Yan Zhou,Guangcheng Dai,Wenfang Zhang,Yuxi Shan
DOI: https://doi.org/10.3760/cma.j.issn.1001-9030.2016.03.046
2016-01-01
Abstract:Objective To investigate the effectiveness of the drainage,degradation and biocompatibility of a novel gradient degradable ureteral stent in a beagle dog model.Methods Ten beagle dogs were randomly divided into 2-,4-,and 6-week groups.The gradient degradable ureteral stent and the ordinary ureteral stent were inserted into each side of the ureter through open operation.Urine and blood tests were performed at 1st,2nd,4th,and 6th week after the operation.Kidney,ureter and bladder (KUB) X-ray radiography or computed tomography (CT) was performed immediately and at 2nd,4th,and 6th week after the operation to observe the degradation of the stent and hydronephrosis.Two,2,and 6 dogs were sacrificed at 2nd,4th,and 6th week after the operation for microscopic and histological evaluation,respectively.Results There were no significant differences in blood test and renal function in either group at any observation time point (P > 0.05).Urinalysis showed the urine pH before (7.30 ± 0.11)and at 1 st,and 4th week after operation (6.80 ± 0.14,6.23 ± 0.13,5.50 ± 0.11,5.00 ± 0.14) showed statistically significant difference (P < 0.05).The count of white blood cells was increased during 1-4 weeks after operation [(264.30 ± 63.36),(137.67 ± 32.49),and (43.50 ± 19.15) × 106/L] and fell back at 6th week [(7.67 ±3.78) × 106/L],but all higher than that of pre-operation [(0.83 ±0.98) ×106/L] with the difference being statistically significant (P < 0.01,P < 0.01,P < 0.01,P < 0.05);The results of the X-ray examination showed that the stents in the experimental groups began to degrade partially at 2nd week.CT scanning showed the stents in the experimental groups practically vanished at 4th week after the operation and the renal cortex and medulla in both sides were enhanced in all periods of the enhanced CT scanning.Gross specimen observation indicated that the kidney paled and plumped with expansion of the renal pelvis,the renal pelvis and ureter mucosa of the experimental side were smooth with no lesions.Histological observation revealed that the renal parenchyma,proximal tubule,distal tubule and interstitial structure were normal at 2nd,4th,and 6th week after implantation.The histological features of the experimental side and control side were similar.Conclusion Animal experiment indicated that the gradient degradable ureteral stent could provide support for about 2 weeks,then degrade in gradient.The degradation segments had a stimulating effect on pelvis and ureter mucosa but do not affect the renal function and drainage.The leading inflammatory reaction disappeared after the stent fully degraded,indicating good biocompatibility of the stent.
What problem does this paper attempt to address?