Dosimetric Comparison between Intensity-modulated Radiotherapy and Helical Tomotherapy for Non-small Cell Lung Cancer

解佳奇,蒋俊,任伟,吕昕,朱丽晶,闫婧
DOI: https://doi.org/10.3969/j.issn.1001-5930.2017.03.039
2017-01-01
Abstract:Objective To compare dose distribution characteristics and differences of helical tomography radiotherapy ( TomoTherapy treatment planning system ) and conventional accelerators static IMRT ( PrecisePlan treatment planning system ) for non-small cell lung cancer (NSCLC) patients.Methods Retrospective analysis and design TomoTherapy and IMRT treat-ment plan ,after the CT image tag target and normal organs were transferred to the TomoTherapy treatment planning system ( Tomo group) and PrecisePlan treatment planning system (IMRT group),GTV give 70Gy/33F dose,clinical target volume give 60Gy/33F dose,normal organs pneumonectomy <30%,spinal cord <45Gy,heart <30%,esophagus <30%,according to the dose distribution ,dose volume histograms ( DVH) and other indicators to compare two dose distribution characteristics .Results GTV radiation dose parameters HI Tomo group 1.047 ±0.015 (cGy),Dmax 7406.2 ±137.1 (cGy) were significantly lower than the IMRT group (P<0.05),HI values closer to 1 Tomo group.Two sets of CI,Dmini,Dmean difference was not significant (P>0.05).PTV radiation dose parameters Tomo group Dmax 7306.4 ±151.4 (cGy),Dmean 6603.8 ±143.7 (cGy) were signifi-cantly lower than the IMRT group (P<0.05),two groups of CI,Dmini,HI difference was not significant (P>0.05).Ipsilateral lung radiation dose parameters Dmax Tomo group ,Dmini,Dmean value IMRT group difference was statistically significant ( P<0.05).Contralateral lung radiation dose parameters Dmax Tomo group ,Dmini,value and IMRT group difference was statistically significant ( P <0 .05 ) , Dmean value difference was not significant ( P >0 .05 ) .Spinal radiation dose parameters Dmean Tomo&nbsp;group,Dmini value IMRT group difference was statistically significant (P<0.05),Dmax comparison value was not significantly different (P>0.05).Heart radiation dose parameters Dmax Tomo group ,Dmean,Dmini value IMRT group difference was not sta-tistically significant (P>0.05).Heart radiation dose parameters Dmini value Tomo group was significantly higher than IMRT group differences were statistically significant (P<0.05),two groups of patients Dmax,Dmean value of the difference was not significant (P>0.05).Conclusion Spiral tomography lung cancer compared with conventional radiotherapy accelerator static IMRT has better uniformity of radiation ,while the adjacent organs radioactive hurt smaller .
What problem does this paper attempt to address?