Femtosecond Laser-Assisted Deep Anterior Lamellar Keratoplasty Using the Big Bubble Technique for Keratoconus

Lu Yan,Chen Xiangfei,Yang Liping,Cao Qian,Wang Chunhong,Huang Zhenping
DOI: https://doi.org/10.3760/cma.j.issn.1674-845x.2015.01.005
2015-01-01
Abstract:Objective To evaluate the clinical results and safety of big bubble deep anterior lamellar keratoplasty assisted by a femtosecond laser for keratoconus.Methods A case series of 11 eyes of 9 keratoconus patients were enrolled in the study.A 500 kHz VisuMax femtosecond laser (Carl Zeiss Meditec AG,Jena,Germany) was used to create a vertical side cut on both donor and recipient corneas.The mean thinnest corneal thickness measured with ultrasound corneal pachymetry,was 359.7±49.8 μm.Preoperative UCVA was counting fingers (CF) to-0.1 and preoperative BCVA was CF to-0.12.The mean donor diameter was 7.51±0.14 mm and mean recipient diameter was 7.38±0.10 mm.Mean follow-up was 7.70±2.88 months.Results All eyes were successfully treated without intraoperative complications.Early postoperative evaluation showed a clear graft in all cases.Mean corneal thickness was 481.4±51.3 μm.A normal corneal topographic pattern was restored.At the last postoperative examination,UCVA was 0.15 to 0.40 and the BCVA was 0.30 to 0.80.Conclusion Our early results indicate that femtosecond laser-assisted deep anterior lamellar keratoplasty using the big bubble technique shows promise as a safe and effective surgical choice in the treatment of keratoconus.